Brymen, BM038F, Fork-clamp Multimeter
GENERAL SPECIFICATIONS
-
Display: 3-5/6 digits 6000 counts
-
Polarity: Automatic
-
Update Rate: 5 per second nominal
-
Operating Temperature: 00C to 400C
-
Relative Humidity: Maximum relative humidity 80% for temperature up to 31 0C decreasing linearly to 50% relative humidity at 400C
-
Pollution degree: 2
-
Storage Temperature: -200C to 600C, < 80% R.H. (with battery removed)
-
Altitude: Operating below 2000m
-
Temperature Coefficient: nominal 0.1 x (specified accuracy)/ 0C @(00C -- 180C or 280C -- 400C), or otherwise specified
-
Sensing: True RMS
-
Safety: Certified per IEC/EN/CSA_C22.2_No./UL standards: 61010-1 Ed. 3.0, 61010-2-032 Ed. 3.0, 61010-2-033 Ed. 1.0, & 61010-031 Ed. 2.0 to
-
Measurement Categories CAT III 600V and CAT IV 300V ac & dc
-
Transient Protection: 6.0kV (1.2/50µs surge)
-
Overload Protections:
Current via jaws: 600Adc/Aac rms at <400Hz
Voltage via terminals: 660Vdc / 920Vac rms
Other functions via terminals: 600Vdc/Vac rms
-
E.M.C.: Meets EN61326-1:2013
-
Power Supply: 1.5V AAA Size battery X 2
-
Power Consumption: 4mA
-
Low Battery Indication:
Below approx. 2.85V for Capacitance & Hz
Below approx. 2.5V for other functions
-
APO Timing: Idle for 32 minutes
-
APO Consumption: 5µA typical
-
Dimension (LxWxH): 193 x 57 x 32mm
-
Weight: 158g
-
Fork-clamp opening & Conductor diameter : 12,5 mm max
-
Accessories: Test lead set, User's manual, Soft carrying pouch, Bkp60 banana plug type-K thermocouple (Model 039F only),
-
Optional purchase accessories: BKB32 banana plug to type-K socket plug adaptor (039F only only)
-
Special Features: Fork-clamp Current Measurement; MAX/MIN Recording mode; MAX/MIN, Crest (Peak-Hold) mode; Relative-Zero mode; Display Hold; EF-Detection (NCV & Single pole);BeepLitTM Feature
ELECTRICAL SPECIFICATIONS
DC Voltage
RANGE |
Accuracy |
600.0V |
1.0% + 5d |
Input Impedance: 10MΩ, 100 pF nominal
AC Voltage (LPF added)
RANGE |
Accuracy |
50Hz ~ 60Hz |
|
600.0V |
1.5% + 5d |
Input Impedance: 10MΩ, 100 pF nominal
Resistance measurement
RANGE |
Accuracy |
600.0Ω, 6.000kΩ (All models) |
1.0% + 5d |
Open Circuit Voltage: 1.0VDC typical
Capacitance measurement (Model 039F only)
RANGE |
Accuracy |
200.0µF, 2500µF |
2.0% + 4d |
BeepLit™ Diode Tester
RANGE |
Accuracy |
3.000V |
1.5% + 5d |
Test Current: 0.3mA typical
Open Circuit Voltage: < 3.5VDC typical
Beep-Alert Threshold: Drop across 0.850V
BeepLit™ ON Threshold: < 0.100V
Audible Indication: Beep sound
Visible Indication: LCD Backlight
DC µA measurement (Model 039F only)
RANGE |
Accuracy |
Burden Voltage |
200.0 µA, 2000µA |
1.0% + 5d |
3.5mV/µA |
Temperature measurement (Model 039F only)
RANGE |
Accuracy |
-40.0 oC ~ 99.9 oC |
1.0% + 1oC |
100 oC ~ 400 oC |
Fork-clamp ACA measurement
RANGE |
Accuracy |
50Hz ~ 60Hz |
|
60.00A |
1.0% + 5d |
Hz (LPF added) Line-Level Frequency (Model 039F only)
Function |
Sensitivity (Sine RMS) |
Range |
600Vac |
50V |
5.00Hz ~ 999.9Hz |
Non-Contact EF-Detection (NCV)
Bar-Graph Indication |
EF-H (Hi Sensitivity) |
EF-L (Lo Sensitivity) |
Typical AC Voltage (Tolerance) |
||
- |
10V (2V ~ 20V) |
40V (10V ~ 70V) |
- - |
20V (4V ~ 40V) |
80V (20V ~ 140V) |
- - - |
40V (8V ~ 70V) |
160V (40V ~ 280V) |
- - - - |
80V (16V ~ 140V) |
320V (80V ~ 560V) |
- - - - - |
160V (40V ~ 600V) |
500V (160V ~ 600V) |
Indication: Bar-graph segments & audible beep tones proportional to the field strength
Detection Frequency: 50/60Hz
Detection Antenna: Inside the top side of the stationary jaw
Probe-Contact EF-Detection (Single-pole Measurement): For more precise indication of live wires, such as distinguishing between live and ground connections, use one single test probe to test via terminal COM for direct metal contact probing to achieve the most distinctive indications.
CREST (Peak-Hold):
Applicability: Voltage and Non-invasion Current functions
Accuracy: Add +/- 250 digits to specified, accuracy for changes > 5ms in duration