Clamp-on Meter CMP-1006

Brand: Sonel
Product code: WMGBCMP1006
Price:
111,00 €excl. VAT
  • AC/DC current measurement (TRUE RMS) up to 1000A.
  • Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)
  • AC/DC voltage measurement (TRUE RMS) up to 600V.
  • Resistance measurement and continuity test:
    - continuity test with acoustic signalling (beeper) for resistance below 40.
  • Temperature measurement (Fahrenheit and Celsius units).
  • Frequency measurement.
  • Duty cycle measurement.
  • Diode test.
  • Additionally:
    - safe, insulated measuring clamps,
    - autoranging/manual range selection,
    - DATA HOLD function, for holding measured values,
    - backlit LCD,
    - DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
    - MAX/MIN function,
    - over range indication,
    - AUTO-OFF function.

Electric security:

  • measurement category: CAT III 600V acc. to EN 61010-1:2004
  • protection class acc. to EN 60529: IP40


Other technical data:

  • power supply: 9V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40Ω; test current < 0,5mA
  • diode test: test current of 0,3mA, typical open circuit voltage < 3V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100ms
  • temperature sensor: type K thermocouple
  • input impedance: 10MΩ (V DC and V AC)
  • AC bandwidth: 50...400Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010-1:2004, EN 61010-2-032
  • quality standard: ISO 9001
Rated operational conditions:
  • internal clamp diameters: d1=36mm/d2=52mm
  • operating temperature: +5...+40°C
  • storage temperature: -20...+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy
(DC)
Accuracy
(AC)
0...659,9A 0,1A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt)
for f=50...60Hz
660...1000A 1A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt)
for f=50...60Hz


DC voltage measurement
Range Resolution Accuracy
0...6,599V 0,001V ±(1,5% m.v. + 3 dgt)
6,60...65,99V 0,01V
66,0...600,0V 0,1V


AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0...6,599V 0,001V ±(1,8% m.v. + 5 dgt)
for f=50...60Hz
6,60...65,99V 0,01V
66,0...600,0V 0,1V

Resistance measurement

Range Resolution Accuracy
0,0...659,9Ω 0,1Ω ±(1,0% m.v. + 4 dgt)
0,660...6,599kΩ 0,001kΩ ±(1,5% m.v. + 2 dgt)
6,60...65,99kΩ 0,01kΩ
66,0...659,9kΩ 0,1kΩ
0,660...6,599MΩ 0,001MΩ ±(2,5% m.v. + 3 dgt)
6,60...66,00MΩ 0,01MΩ ±(3,5% m.v. + 5 dgt)

Frequency measurement

Range Resolution Accuracy
30,0...999,9Hz 0,1Hz ±(1.2% m.v. + 2 dgt)
sensitivity:30...5kHz:10Vrms min.
5kHz...15kHz:40Vrms min.
for 20%...80% duty cycle
1,000...9,999kHz 0,001kHz
10,00...15,00kHz 0,01kHz

Temperature measurement

Range Resolution Accuracy
-20...760°C 0,1°C ±(3,0% m.v. + 5°C)
-4...1400°F 0,1°F ±(3,0% m.v. + 9°F)

Duty cycle measurement

Range Resolution Accuracy
10,0...94,9% 0,1% ±(1,2% m.v. + 2 dgt)

• pulse width: 100μs...100ms,
?• frequency range: 30Hz...5kHz,
• sensitivity: 30Hz...5kHz: 10Vrms, 5kHz...15kHz: 40Vrms.

„m.v.”- measured value