Temperature |
-40 to 550 °C (-40 to 1022 ° F) |
Display Resolution |
0.1°C (0.1 °F) of reading |
D:S (Distance to spot size) |
12:1 |
Easy Emissivity Selector |
Adjustable with three settings: Low (0.3), Medium (0.7). High (0.95) |
Display Accuracy [Assumes ambient operating temperature of 23°C(73°F) to 25°C(77°F)] |
±1.0 % of reading ±1 % of reading or ±1 °C (±2 °F), whichever is greater below 0 °C/32 °F, ±1 °C (±2 °F) ± 0.1°/1° |
Response Time |
500 mSec (95 % of reading) |
Repeatability |
±0.5 % of reading or ±1 °C (±2 °F), whichever is greater |
Spectral Response |
8 µm to 14 µm |
Laser Sighting |
Single point laser |
Laser Shutoff |
Laser turns off above ambient temperature of 40 °C (104 °F) |
Laser Power |
Class 2(II) operation; Output <1mW, wavelength 630-670 nm |
Relative Humitity |
10 % to 90 % RH non-condensing, at <30 °C (86 °F) |
Power, battery life |
2 AA batteries (alkaline or NiCD) |
Battery Life |
12 hours |
Display Hold |
7 seconds |
Backlit Display |
Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
Warranty |
2 years |
Operating Temperature |
0 °C to 50 °C (32 °F to 120 °F) |
Storage Temperature |
-20 °C to 65 °C (-25 °F to 150 °F) |
MAX, MIN, DIF Temperatures |
Yes |
Thermocouple Type K Mini Adapter Input |
Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. |
Thermocouple Type K Fabric Hook-and-Loop Fastener Pipe Probe |
Yes, with a temperature range of 0 °C to 100 °C (32 °F to 212 °F) and accuracy of ±2.2 °C (±4 °F) |
HVAC Measurement Guide |
Yes |