AC/DC voltage measurement up to 600V.
Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 50.
Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Capacitance measurement .
Diode test.
Additionally:
- safe, insulated measuring clamps,
- double molded housing,
- autoranging/manual range selection,
- DATA HOLD function, for holding measured values,
- backlit LCD,
- REL function,
- over range indication,
- AUTO-OFF function.
- DC current measurement and AC current. .
- AC/DC voltage measurement up to 600V.
- Resistance measurement and continuity test:
- continuity test with acoustic signalling (beeper) for resistance below 50Ω.
- Temperature measurement (Fahrenheit and Celsius units).
- Frequency measurement.
- Capacitance measurement
- Diode test.
- Additionally:
- safe, insulated measuring clamps,
- double molded housing,
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- backlit LCD,
- „REL” function,
- over range indication,
- „AUTO-OFF” function.
Electric security:
- measurement category: CAT III 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529: IP40
Other technical data:
- power supply: 9V battery type 6LR61
- display: 4000 counts, backlit LCD
- continuity test: I<0,5mA, sound signal for R<50Ω
- diode test: I=0,3mA, U0=1,5V DC
- over range indication: 0L displayed
- sampling rate: 2 times per second
- input impedance: 10MΩ (V DC and V AC)
- clamp size: opening 30mm (1,2”)
- auto power OFF: approx. 30 min.
- dimensions: 197 x 70 x 40 mm
- weight: 183 g
- accordance with following standards: EN 61010-1:2004, EN 61010-2-032
- quality standard: ISO 9001
Rated operational conditions:
- operating temperature: 0...+40°C
- storage temperature: -20...+60°C
- operating humidity:
max 80% up to 31°C
decreasing linearly to 50% at 40°C
- operating altitude: max 2000 m
Temperature measurement
Range | Accuracy* |
-20,0...760°C | ±(3% m.v. + 5°C) |
-4,0...1400°F | ±(3% m.v. + 9°F) |
*probe (K type) accuracy not included
Frequency measurement
Range | Accuracy |
10Hz ... 10kHz | ±(1,5% m.v. + 2 digits) |
- csensitivity: 100V(<50Hz), 50V(50…400Hz); 15V(401Hz…10kHz)
AC current measurement
Range | Resolution | Accuracy |
4,000 A | 0,001 A | no range |
40,00 A | 0,01 A | ±(2,5% m.v. + 8 digits) |
400,0 A | 0,1 A | ±(2,8% m.v. + 8 digits) |
- ?frequency range: 50...60Hz.
DC current measurement
Range | Resolution | Accuracy |
40,00 A | 0,01 A | ±(2,5% m.v. + 5 digits) |
400,0 A | 0,1 A | ±(2,8% m.v. + 5 digits) |
AC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,1 mV | ±(1,5% m.v. + 30 digits) |
4,000 V | 0,001 V | ±(1,5% m.v. + 5 digits) |
40,00 V | 0,01 V | |
400,0 V | 0,1 V | |
600,0 V | 0,1 V | ±(2% m.v. + 5 digits) |
- frequency range: 50...400Hz.
Range | Resolution | Accuracy |
400,0 mV | 0,1 mV | ±(0,8% m.v. + 2 digits) |
4,000 V | 0,001 V | ±(1,5% m.v. + 2 digits) |
40,00 V | 0,01 V | |
400,0 V | 0,1 V | |
600,0 V | 0,1 V | ±(2% m.v. + 2 digits) |
Resistance measurement
Range | Resolution | Accuracy |
400,0 Ω | 0,1 Ω | ±(1,0% m.v. + 4 digits) |
4,000 kΩ | 0,001kΩ | ±(1,5% m.v. + 2 digits) |
40,00 kΩ | 0,01 kΩ | |
400,0 kΩ | 0,1 kΩ | |
4,000 MΩ | 0,001 MΩ | ±(2,5% m.v. + 3 digits) |
40,00 MΩ | 0,01 MΩ | ±(3,5% m.v. + 5 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,00 nF | 0,01 nF | ±(4% m.v. + 20 digits) |
400,0 nF | 0,1 nF | ±(3% m.v. + 5 digits) |
4,000 nF | 0,001 μF | |
40,00 nF | 0,01 μF | |
100,0 nF | 0,1 μF | ±(4% m.v. + 10 digits) |
„m.v.”- measured value